Loop Detector Barrier Gate Winmax-BG-06
$39.9
$67.43
Loop Detector Barrier Gate Winmax-BG-06 Loop Detector ระบบไม้กั้นรถยนต์อัตโนมัติ Winmax-BG-06 Product Details Power Supply: 230V AC, 115V AC, 24V DC/AC, 12V DC/AC (refer to the label on the detector) AC Voltage Tolerance: 10% / -15% DC Voltage Tolerance: ±15% Power Consumption: 4.5VA Relay Output: 240V / 5A Operating Temperature: -20 ºC ~ 65 ºC Storage Temperature: -40 ºC ~ 85 ºC Frequency Range: 20 kHz ~ 170 kHz Response Time: 10 ms Sensitivity Adjustment: Adjustable in 4 levels Loop Inductance: Series wiring inductance: 50μH to 1000μH (typical: 100μH to ø300μH) Parallel Wiring Connection: Maximum length 20 meters, twisted at least 20 turns per meter Housing Dimensions: L78 x W40 x H108 mm Operation and Status Indication During detector initialization, the green channel LED and red power LED will light up for about 2 seconds, then the green LED will turn off. If there is a wiring fault, the channel LED will remain on and blink to indicate the malfunction. If the fault is self-correcting, the detector will continue operating. The green channel LED lights up when a vehicle is detected passing over the induction loop. The red power LED on top of the unit remains lit to indicate the device is powered. Automatic Sensitivity Boost The automatic sensitivity boost can be selected via DIP switch 5 on the front panel. OFF = Disabled ON = Enabled When enabled, the sensitivity will automatically increase to the maximum level while a vehicle is over the loop, maintaining this level during vehicle presence. Once the vehicle leaves the loop, the detector reverts to the preset sensitivity level.
Automatic Barrier Gate